Cary 100/300 tablet dissolution system configurations

Single bath Cary VK-7000 tablet dissolution system
|
Description |
Part number |
|
Cary 100 Tablet* and ACB |
0010071700 |
|
or |
|
|
Cary 300 Tablet* and ACB |
0010071800 |
|
*These systems include as standard:
| 8x6 Ambient cell block |
| Extended sample compartment |
| Dissolution manifold |
| Dissolution system instruction sheet |
| Bath cable kit | |
|
|
Cary WinUV Tablet software package |
8510158300 |
|
Flow cells. At least 6 of one type of cells will be required |
|
|
10 mm Pathlength Dissolution Flowcell |
6 x 6610015200 |
|
and/or |
|
|
5 mm Pathlength Dissolution Flowcell |
6 x 6610014300 |
|
and/or |
|
|
2 mm Pathlength Dissolution Flowcell |
6 x 6610014200 |
|
and/or |
|
|
1 mm Pathlength Dissolution Flowcell |
6 x 6610014100 |
|
The Dissolution baths systems can be ordered directly from Varian. These kits contain :
| One VK-7000 Dissolution testing station, 7 spindle, 8 Vessel |
| One Automated sampling manifold |
| Seven Teflon coated paddles or baskets |
| Seven 1 L clear glass vessels and lids |
| One 100mL standard vessel and lid |
| One VK 750D Extenal heater circulator and tubing |
| One 8 channel peristaltic pump |
| One set of full flow filter tips 35 um, pack of 100 |
Choose one of the following: |
|
|
10-6900VK 7000, Varian, with Paddles (115V) |
9910089700 |
|
10-6910 VK 7000, Varian, with Baskets (115V) |
9910089900 |
|
10-7000VK 7000, Varian, with Paddles (240V) |
9910089800 |
|
10-7010 VK 7000, Varian, with Baskets (240V) |
9910090000 |
|
Optional |
|
|
12-0105 Dosage Delivery Module, 7 position for above baths. |
7910031000 |
More information and spares
Choose the appropriate Country Kit from below:
|
Country Kit |
Part number |
|
Australia |
9810026000 |
|
USA |
9810026100 |
|
Europe |
9810026200 |
|
Description |
Part number |
|
Cary 100 Tablet* and ACB |
0010071700 |
|
or |
|
|
Cary 300 Tablet* and ACB |
0010071800 |
|
*These systems include as standard:
| Sample transport Accessory |
| 8x6 Ambient cell block |
| Extended sample compartment |
| Dissolution manifold |
| Dissolution system instruction sheet |
| Bath cable kit | |
|
|
Cary WinUV Tablet software package |
8510158300 |
|
Flow cells. At least 6 and up to 7 of two types of cells form below will be required (12 to 14 cells in total) |
|
|
10 mm Pathlength Dissolution Flowcell |
6610015200 |
|
5 mm Pathlength Dissolution Flowcell |
6610014300 |
|
2 mm Pathlength Dissolution Flowcell |
6610014200 |
|
1 mm Pathlength Dissolution Flowcell |
6610014100 |
|
Dual pathlength connecting tubing (Front to rear cells). Includes 9 tubes. |
6610020400 |
|
The Dissolution baths systems can be ordered directly from Varian. These kits contain :
| One VK-7000 Dissolution testing station, 7 spindle, 8 Vessel |
| One Automated sampling manifold |
| Seven Teflon coated paddles or baskets |
| Seven 1000mL clear glass vessels and lids |
| One 100mL standard vessel and lid |
| One VK 750D Extenal heater circulator and tubing |
| One channel peristaltic pump |
| One set of full flow filter tips 35 um, pack of 100 |
Choose one of the following: |
|
|
10-6900VK 7000, Varian, with Paddles (115V) |
9910089700 |
|
10-6910 VK 7000, Varian, with Baskets (115V) |
9910089900 |
|
10-7000VK 7000, Varian, with Paddles (240V) |
9910089800 |
|
10-7010 VK 7000, Varian, with Baskets (240V) |
9910090000 |
|
Optional |
|
|
12-0105 Dosage Delivery Module, 7 position for above baths. |
7910031000 |
More information and spares
Choose the appropriate Country Kit from below:
|
Country Kit |
Part number |
|
Australia |
9810026000 |
|
USA |
9810026100 |
|
Europe |
9810026200 |
|
Description |
Part number |
|
Cary 100 Tablet and ACB |
0010071700 |
|
or |
|
|
Cary 300 Tablet and ACB |
0010071800 |
|
These systems include as standard:
| Sample transport Accessory |
| 8x6 Ambient cell block |
| Extended sample compartment |
| Dissolution manifold |
| Dissolution system instruction sheet |
| Bath cable kit | |
|
|
Cary WinUV Tablet software package |
8510158300 |
|
Flow cells. At least 12 cells will be required. At least 6 (and up to 7) of each type is required. |
|
|
10 mm Pathlength Dissolution Flowcell |
12 x 6610015200 |
|
and/or |
|
|
5 mm Pathlength Dissolution Flowcell |
12 x 6610014300 |
|
and/or |
|
|
2 mm Pathlength Dissolution Flowcell |
12 x 66 10014200 |
|
and/or |
|
|
1 mm Pathlength Dissolution Flowcell |
12 x 6610014100 |
|
5 mm Pathlength Dissolution Flowcell |
12 x 6610015200 |
|
and/or |
|
|
2 mm Pathlength Dissolution Flowcell |
12 x 6610014300 |
|
and/or |
|
|
1 mm Pathlength Dissolution Flowcell |
12 x 6610014100 |
|
The Dissolution baths systems can be ordered directly from Varian. These kits contain :
| Two VK-7000 Dissolution testing station, 7 spindle, 8 Vessel |
| Two Automated sampling manifold |
| Fourteen Teflon coated paddles or baskets |
| Fourteen 1000mL clear glass vessels and lids |
| Two 100mL standard vessels and lids |
| One VK 750D Extenal heater circulator and tubing |
| One 16 channel peristaltic pump |
| One set of full flow filter tips 35 um, pack of 100 | |
|
|
Two bath communicator set (Cables) |
9910097400 |
|
The Dissolution baths systems can be ordered directly from Varian. Choose one of the following: |
|
|
2 Bath 10-7020, VK 7000, Varian, with Paddles (115V) |
7910030600 |
|
2 Bath 10-7030, VK 7000, Varian, with Baskets (115V) |
7910030800 |
|
2 Bath10-7040, VK 7000, Varian, with Paddles (240V) |
7910030700 |
|
2 Bath 10-7050, VK 7000, Varian, with Baskets (240V) |
7910030900 |
|
Optional |
|
|
12-0105 Dosage Delivery Module, 7 position for above baths. One required for each bath |
7910031000 |
More information and spares
Choose the appropriate Country Kit from below:
|
Country Kit |
Part number |
|
Australia |
9810026000 |
|
USA |
9810026100 |
|
Europe |
9810026200 | |
 |

The Cary 100/300 dissolution manifold
|