Cary 100/300 tablet dissolution system configurations

Single bath systems
Dual pathlength systems
Two bath systems

Single bath Cary VK-7000 tablet dissolution system

Description

Part number

Cary 100 Tablet* and ACB

0010071700

or

Cary 300 Tablet* and ACB

0010071800

*These systems include as standard:

8x6 Ambient cell block
Extended sample compartment
Dissolution manifold
Dissolution system instruction sheet
Bath cable kit

Cary WinUV Tablet software package

8510158300

10 mm Pathlength Dissolution Flowcell

6 x 6610015200

and/or

5 mm Pathlength Dissolution Flowcell

6 x 6610014300

and/or

2 mm Pathlength Dissolution Flowcell

6 x 6610014200

and/or

1 mm Pathlength Dissolution Flowcell

6 x 6610014100

The Dissolution baths systems can be ordered directly from Varian. These kits contain :

One VK-7000 Dissolution testing station, 7 spindle, 8 Vessel
One Automated sampling manifold
Seven Teflon coated paddles or baskets
Seven 1 L clear glass vessels and lids
One 100mL standard vessel and lid
One VK 750D Extenal heater circulator and tubing
One 8 channel peristaltic pump
One set of full flow filter tips 35 um, pack of 100

Choose one of the following:

10-6900VK 7000, Varian, with Paddles (115V)

9910089700

10-6910 VK 7000, Varian, with Baskets (115V)

9910089900

10-7000VK 7000, Varian, with Paddles (240V)

9910089800

10-7010 VK 7000, Varian, with Baskets (240V)

9910090000

Optional

12-0105 Dosage Delivery Module, 7 position for above baths.

7910031000

More information and spares

Country Kit
Part number
Australia
9810026000
USA
9810026100
Europe
9810026200

Dual pathlength for one bath Cary VK-7000  tablet dissolution system

Description

Part number

Cary 100 Tablet* and ACB

0010071700

or

Cary 300 Tablet* and ACB

0010071800

*These systems include as standard:

Sample transport Accessory
8x6 Ambient cell block
Extended sample compartment
Dissolution manifold
Dissolution system instruction sheet
Bath cable kit

Cary WinUV Tablet software package

8510158300

Flow cells. At least 6 and up to 7 of two types of cells form below will be required (12 to 14 cells in total)

10 mm Pathlength Dissolution Flowcell

6610015200

5 mm Pathlength Dissolution Flowcell

6610014300

2 mm Pathlength Dissolution Flowcell

6610014200

1 mm Pathlength Dissolution Flowcell

6610014100

Dual pathlength connecting tubing (Front to rear cells). 
Includes 9 tubes.

6610020400

The Dissolution baths systems can be ordered directly from Varian. These kits contain :

One VK-7000 Dissolution testing station, 7 spindle, 8 Vessel
One Automated sampling manifold
Seven Teflon coated paddles or baskets
Seven 1000mL clear glass vessels and lids
One 100mL standard vessel and lid
One VK 750D Extenal heater circulator and tubing
One channel peristaltic pump
One set of full flow filter tips 35 um, pack of 100

Choose one of the following:

10-6900VK 7000, Varian, with Paddles (115V)

9910089700

10-6910 VK 7000, Varian, with Baskets (115V)

9910089900

10-7000VK 7000, Varian, with Paddles (240V)

9910089800

10-7010 VK 7000, Varian, with Baskets (240V)

9910090000

Optional

12-0105 Dosage Delivery Module, 7 position for above baths.

7910031000

More information and spares

Country Kit
Part number
Australia
9810026000
USA
9810026100
Europe
9810026200

Two bath Cary VK-7000 tablet dissolution system

Description

Part number

Cary 100 Tablet and ACB

0010071700

or

Cary 300 Tablet and ACB

0010071800

These systems include as standard:

Sample transport Accessory
8x6 Ambient cell block
Extended sample compartment
Dissolution manifold
Dissolution system instruction sheet
Bath cable kit

Cary WinUV Tablet software package

8510158300

10 mm Pathlength Dissolution Flowcell

12 x 6610015200

and/or

5 mm Pathlength Dissolution Flowcell

12 x 6610014300

and/or

2 mm Pathlength Dissolution Flowcell

12 x 66 10014200

and/or

1 mm Pathlength Dissolution Flowcell

12 x 6610014100

5 mm Pathlength Dissolution Flowcell

12 x 6610015200

and/or

2 mm Pathlength Dissolution Flowcell

12 x 6610014300

and/or

1 mm Pathlength Dissolution Flowcell

12 x 6610014100

The Dissolution baths systems can be ordered directly from Varian. These kits contain :

Two VK-7000 Dissolution testing station, 7 spindle, 8 Vessel
Two Automated sampling manifold
Fourteen Teflon coated paddles or baskets
Fourteen 1000mL clear glass vessels and lids
Two 100mL standard vessels and lids
One VK 750D Extenal heater circulator and tubing
One 16 channel peristaltic pump
One set of full flow filter tips 35 um, pack of 100

Two bath communicator set (Cables)

9910097400

The Dissolution baths systems can be ordered directly from Varian. Choose one of the following:

2 Bath 10-7020, VK 7000, Varian, with Paddles (115V)

7910030600

2 Bath 10-7030, VK 7000, Varian, with Baskets (115V)

7910030800

2 Bath10-7040, VK 7000, Varian, with Paddles (240V)

7910030700

2 Bath 10-7050, VK 7000, Varian, with Baskets (240V)

7910030900

Optional

12-0105 Dosage Delivery Module, 7 position for above baths. One required for each bath

7910031000

More information and spares

Country Kit
Part number
Australia
9810026000
USA
9810026100
Europe
9810026200