Automated Systems
Total Solution
Agilent Single- and Multi-Bath Drivers
VK 8000 Dissolution Sampling Station
VK 8020 Sample Collector
VK 806 Syringe Pump
VK 808 Filter Changer
Peristaltic Pump
VK 750D Heater / Circulator
VK 905 Mobile Vessel Washing Station
Consumables

VK 808 Filter Changer

Highlights

  • Automatic filter changing between each sampling time point
  • Special 25 mm filters designed for automation
  • Standard nylon and PVDF filters—other membrane materials available
  • Pore sizes down to 0.45 micron

The Filter Changer is designed to be used in conjunction with the VK 8000 or VK 8080. This unit can easily be added to an existing autosampler (a Syringe Pump and new chip for the VK 8000 are required).

The Filter Changer is available in 2 models. One version is designed to filter 6, 7 or 8 lines simultaneously—as would typically be done when using the VK 8000. Another version utilizes a single line and is used with the VK 8000 (see page 106). In this setup, only 1 filter is placed in line. In this application, a sequential injection onto an HPLC column is filtered prior to injection.

The Filter Changer can store up to 200 filters at a time. The filters come prepackaged in tubes of 25 for easy loading. See page 103 for automation filters.

When used with the VK 8000, all of the parameters are set using the VK 8000 keypad. The sequence of events is as follows:

  • The Filter Changer is in line between the Syringe Pump and the VK 8000.
  • Once the sampling manifold is lowered, a multichannel Syringe Pump pulls media from the vessel.
  • A series of pulls is required to fill the lines of the VK 8000.
  • Once the lines are full, the valves in the VK 8000 are opened and the Syringe Pump fills the tubes or vials in the sample tray with filtered sample.
  • The valves in the VK 8000 are then closed and the remaining media in the line is pushed from the lines.
  • Then the filters are ejected from the lines and new filters are rotated into position.

You are assured of the proper sample being withdrawn due to the accuracy of the Syringe Pumps. These syringes have an accuracy of ± 2% when used with the Filter Changer and ± 1% when used without the Filter Changer.

You can order the Filter Changer to retrofit existing VK 8000s. For these systems a new chip is installed in the VK 8000 and the unit is retrofitted with a Syringe Pump to replace the existing Peristaltic Pump. Use the single-channel Filter Changer with the VK 8080 Sample Processing Station.