Varian, Inc.
关于我们             产品             支持培训             联系我们             网上商店
inspiring excellence

Diagnostics
On-Site? CupKit™
OnTrak TesTcup?
OnTrak TesTcup? II
OnTrak TesTstik™
OnTrak TesTcard™ 9
On-Site? Alcohol
On-Site? OraLab?
OnTrak OraTube™
SMARTdata Solutions

The step-by-step OnTrak TesTcard™ 9 process


Specimen application option 1


 


1.
Collect specimen in a new specimen cup. Gently tear open the foil pouch to remove the device.

 

 


2. Fill the pipette provided by squeezing firmly on the large pipette bulb, placing the pipette into the sample and releasing pressure on the bulb.

 

 


3. Place the tip of the pipette over the sample well located above the word “Sample” on the TesTcard 9 device and squeeze the bulb to dispense the specimen into the well.

 

 


4. Allow the test to proceed until a blue band forms in the “Test Valid” area (see example) for each strip. The TesTcard 9 device may be placed flat or held face up, horizontally while the test is developing. Test is not complete until a blue band forms in the “Test Valid” area. Once the “Test Valid” line appears, read and record results.

Note: a smear of color will be observed as the reaction proceeds along each test strip. Wait for this to clear.

 


 


Results

The presence of a blue band below the test name indicates a negative result. The lack of color below the test name indicates a positive result. In this example, methamphetamine is positive and the remainder of the test results are negative.

Note: The horizontal location of the bands indicating a negative result may vary.


Specimen application option 2



1. Collect specimen in a new specimen cup. Gently tear open the foil pouch to remove the device.


 


2. Gently immerse the TesTcard 9 device into the specimen until the specimen reaches the bottom of the TesTcard 9 name on the device and immediately remove. Do not immerse the entire device into the specimen.


 


3. Remove the TesTcard 9 device from the specimen by tapping the device along the inside edge of the cup to remove excess sample.


 


4. Allow the test to proceed until a blue band forms in the “Test Valid” area (see example) for each strip. The TesTcard 9 device may be placed flat or held face up, horizontally while the test is developing. Test is not complete until a blue band forms in the “Test Valid ” area. Once the “Test Valid ” line appears, read and record results.

Note: a smear of color will be observed as the reaction proceeds along each test strip. Wait for this to clear.


 


Results

The presence of a blue band below the test name indicates a negative result. The lack of color below the test name indicates a positive result. In this example, methamphetamine is positive and the remainder of the test results are negative.

Note: The horizontal location of the bands indicating a negative result may vary.